Allegion Schlage AD, LE, and NDE Series lock integration through Mercury requires a Mercury EP, LP, MP, or Honeywell controller. If the AD Series locks are disconnected from their controller, the locks can’t grant access or store offline events. However, the mechanical key, and the inside handle, can still be used to open the door.

Synergis™ Softwire 11.5.3 supports the following Allegion Schlage lock features.
The following is the legend for some common values found in the Supported column:
Yes
Synergis Softwire supports the feature and the interface module offers it.
No
Synergis Softwire does not support the feature, but the interface module offers it.
Not applicable
The interface module does not offer the feature.
Features Supported
General characteristics  
Category of interface module Electronic lock
Communication protocol 1 RS-485, radio, Bluetooth
Encrypted communication Yes2
Online operation (connected to the Synergis unit)  
Standalone mode Not applicable
Supervised mode No
Dependent mode Yes
Offline operation (no connection to the Synergis unit)  
Standalone mode Not applicable
Degraded mode No
Wireless operation Yes3
Contact the Synergis unit on event NDE & LE locks
Polling interval Yes
Scheduled radio contact (Status report interval) On lock (NDE & LE)
Battery checks Yes
Power fail lock settings (Fail Safe/Fail Secure) On lock (NDE & LE)
ENGAGE integration NDE & LE locks
Scalability  
Maximum number of offline events Not applicable
Maximum number of credentials (for autonomous decision making) Not applicable
Maximum credential length (in bits) 644
Maximum number of interface modules per Synergis unit RS-485 channel 325
Recommended maximum number of interface modules per Synergis unit Not applicable6

1 The Allegion Schlage lock communicates with the Mercury controller using RS-485 (AD-300), or radio (AD-400). The Mercury controller communicates with the Synergis™ unit over IP. LE and NDE locks connect to the ENGAGE Gateway over Bluetooth.

2 The AD-400 (wireless lock) communicates over a 900 MHz channel using AES-128 bit encryption.

3 The AD-400 model is a wireless lock. Requires the PIM400 communication module. NDE and LE locks require an ENGAGE Gateway.

4 The credential limit of the default configuration. Up to eight different credential lengths are supported.

5 EP2500, LP2500, and MP2500 controllers each have two RS-485 channels, for a maximum of up to 64 interfaces, or 32 interfaces per channel.

EP1501, LP1501, or MP1501 controllers have one RS-485 channel, which supports up to 8 interfaces.

6 In the Allegion Schlage lock integration, it’s the Mercury controller that is viewed as the interface module, not the Allegion Schlage lock. For the recommended number of Mercury controllers per Synergis unit, see Supported Mercury controller features in Synergis Softwire 11.5.3.