For DDS integration, each DDS door controller is viewed as an interface module.
Synergis™ Softwire 11.5.3 supports the following DDS hardware
devices:
Model | Description | Firmware |
---|---|---|
AS34 or TPL | Door controller supporting RS-485 communication, featuring four Wiegand
readers, suitable for two Card in/Card out doors. NOTE: Ensure that the ROM chip
installed on the U5 socket of the TPL board is labeled
5xxx1.
|
You can apply the recommended firmware from the Interface upgrade page of the Synergis™ Appliance Portal. |
AS34-P4 or TPL-P4 | Door controller supporting RS-485 communication, featuring four Wiegand
readers, suitable for four Card in/REX out doors. NOTE: Ensure that the ROM chip
installed on the U5 socket of the TPL board is labeled
6xxx1.
|
|
JET | Door controller supporting RS-485 communication, featuring four Wiegand
readers, suitable for either two Card in/Card out doors or four Card in/REX out
doors2. NOTE: The ROM chip installed on the U5 socket of the JET board
must be labeled 5xxx to enable two-door capability, or 6xxx to enable four-door
capability1.
|
|
EXT-TCPT | TCP/IP extension board for the TPL door controller. | Not applicable |
EXT-8E4S | TCP/IP extension board adding eight supervised inputs and four outputs to the
TPL door controller with the ROM chip 6xxx1. This combination is equivalent to adding a TCP/IP interface to the TPL-P4 controller. |
Not applicable |
JET extension board | Extension board adding eight supervised inputs2 and four outputs to the JET door controller. | Not applicable |
1 The exact chip number depends on the storage capacity of the ROM.
2 Input states when the resistance value is at 9.4 kohms might be incorrect because DDS four-state supervision is 4.7 kohm/4.7 kohm and has a narrow range at the 9.4 kohm value.