Supported DDS devices in Synergis Softwire 11.5.3 - Synergis Softwire 11.5.3

Synergis™ Softwire Integration Guide 11.5.3

Product
Synergis Softwire
Content type
Guides > Integration guides
Version
11.5
Release
11.5.3
ft:locale
en-US
Last updated
2025-01-23

For DDS integration, each DDS door controller is viewed as an interface module.

Synergis™ Softwire 11.5.3 supports the following DDS hardware devices:
Model Description Firmware
AS34 or TPL Door controller supporting RS-485 communication, featuring four Wiegand readers, suitable for two Card in/Card out doors.
NOTE: Ensure that the ROM chip installed on the U5 socket of the TPL board is labeled 5xxx1.
You can apply the recommended firmware from the Interface upgrade page of the Synergis™ Appliance Portal.
AS34-P4 or TPL-P4 Door controller supporting RS-485 communication, featuring four Wiegand readers, suitable for four Card in/REX out doors.
NOTE: Ensure that the ROM chip installed on the U5 socket of the TPL board is labeled 6xxx1.
JET Door controller supporting RS-485 communication, featuring four Wiegand readers, suitable for either two Card in/Card out doors or four Card in/REX out doors2.
NOTE: The ROM chip installed on the U5 socket of the JET board must be labeled 5xxx to enable two-door capability, or 6xxx to enable four-door capability1.
EXT-TCPT TCP/IP extension board for the TPL door controller. Not applicable
EXT-8E4S TCP/IP extension board adding eight supervised inputs and four outputs to the TPL door controller with the ROM chip 6xxx1.

This combination is equivalent to adding a TCP/IP interface to the TPL-P4 controller.

Not applicable
JET extension board Extension board adding eight supervised inputs2 and four outputs to the JET door controller. Not applicable

1 The exact chip number depends on the storage capacity of the ROM.

2 Input states when the resistance value is at 9.4 kohms might be incorrect because DDS four-state supervision is 4.7 kohm/4.7 kohm and has a narrow range at the 9.4 kohm value.