Not all Synergis™ appliance features are supported with the integration of ASSA ABLOY IP locks.
The ASSA ABLOY IP lock integration supports the following Synergis™ Appliance Portal
and Synergis™ Softwire features. For a description of these features, see the Synergis™ Appliance Configuration Guide or the Synergis™ Cloud Link Administrator Guide.
| Synergis Appliance Portal and firmware features | Supported |
|---|---|
| Hardware configuration (pre-staging capability) | |
| Manual enrollment (Add hardware dialog box) | See note1 |
| Automatic enrollment (Scan button) | Yes |
| Property configuration | No |
| Configuration cloning (Clone button) | No |
| I/O diagnostics (live monitoring of inputs, relays, and readers) | No |
| Interface module firmware display | Yes |
| Interface module firmware upgrade | No2 |
| Double-badge activation | Yes3 |
| Access control behavior (Synergis unit-wide settings) 4 | |
| Interlock setting (Single door unlock or Single door open) | No |
| Do not generate Door open too long events when door is unrestricted | Yes |
| Reader setting (Card or PIN or Card only) | Yes |
| Maximum PIN length in digits | 65 |
1 You need to pair the IP lock with the Synergis unit.
2 Only supported on versions earlier than 3_0p10_cx_v4011.
3 See "Enabling passage mode on ASSA ABLOY IP locks" in the Synergis Appliance Configuration Guide or the Synergis Cloud Link Administrator Guide.
4 The door behavior settings are overwritten by the individual door settings configured in Security Center.