Not all Synergis™ appliance features are supported with the integration of Aperio-enabled locks from ASSA ABLOY.
The Aperio-enabled lock integration supports the following Synergis™ Appliance Portal
and Synergis™ Softwire features. For a description of these features, see the Synergis™ Appliance Configuration Guide or the Synergis™ Cloud Link Administrator Guide.
| Synergis Appliance Portal and firmware features | Supported |
|---|---|
| Hardware configuration (pre-staging capability) | |
| Manual enrollment (Add hardware dialog box) | Yes |
| Automatic enrollment (Scan button) | Yes |
| Property configuration | Limited1 |
| Configuration cloning (Clone button) | Yes |
| I/O diagnostics (live monitoring of inputs, relays, and readers) | Yes2 |
| Interface module firmware display | Hub only |
| Interface module firmware upgrade | No |
| Double-badge activation | Yes |
| Access control behavior (Synergis unit-wide settings) 3 | |
| Interlock setting (Single door unlock or Single door open) | No |
| Do not generate Door open too long events when door is unrestricted | Yes |
| Reader setting (Card or PIN or Card only) | Yes |
| Maximum PIN length in digits | 154 |
1 Connection parameters only.
2 Output relays set on the I/O diagnostics page might not take effect immediately, depending on the Status report interval and the Polling interval (v3 locks only) settings.
3 The door behavior settings are overwritten by the individual door settings configured in Security Center.
4 PINs with fewer than four digits aren’t accepted.