Not all Security Center access control features are supported with the integration of Aperio-enabled locks from ASSA ABLOY.
The Aperio-enabled lock integration supports the following Security Center access
control features.
The following is the legend for some common
values found in the Supported column:
- Yes
- Feature is supported by this integration.
- Limited
- Part of the feature is not supported.
- No
- Feature is not supported by this integration.
- Online
- Feature is supported only when the interface module is connected to the Synergis unit.
- Not applicable
- Feature does not apply to this integration.
Feature group | Security Center feature | Supported |
---|---|---|
Door behavior settings (overrides the Synergis unit-wide settings) | Maintenance mode (keep door unlocked and ignore all access events) | Yes |
Standard grant time | Yes | |
Extended grant time | Yes | |
Entry time (Standard/Extended) | No | |
Door relock - options | No | |
When door is unlocked by schedule - options | Yes | |
Door held - options | Limited 1 | |
Door forced open - options | Limited1 | |
Unlock schedules | Limited 2 | |
Request to exit (REX) options | ||
Unlock on REX (On/Off) | No3 | |
Time to ignore REX after granting access (in seconds) | Yes | |
Ignore REX events while door is open (On/Off) | Yes | |
Time to ignore REX after door closes (in seconds) | Yes | |
Visitor escort and two-person rule | ||
Maximum delay between card presentation (in seconds) | Yes | |
Enforce two-person rule (On/Off) on Door side | Yes | |
Manual actions on doors in Security Desk 4 | Manually unlock doors | v3 locks only |
Reader shunting (activate/deactivate reader) | Yes | |
Override unlock schedules | Yes2 | |
Live event monitoring in Security Desk | Module running state (Online, Offline) | Yes |
AC fail | Not applicable | |
Battery fail (Low battery) | Yes | |
Door open/closed | Yes | |
Door locked/unlocked | Yes | |
Door forced open | Yes | |
Door held open for too long | Yes | |
Duress PIN | Yes | |
Deadbolt locked/unlocked | Yes5 6 | |
Key override | Limited7 | |
Area restrictions (for secured areas) | Minimum security clearance (part of threat level management) | Yes |
Visitor escort rule (On/Off) | Yes | |
Visitor escort with turnstile - Single passage mode | Not applicable | |
Visitor escort with turnstile - Delegation mode | Not applicable | |
Interlock | Yes | |
Antipassback | ||
Hard (log and deny access on Antipassback violation) | Limited8 | |
Presence timeout (forget area presence after a certain delay) | Yes | |
Strict (antipassback checked on both area entrance and exit) | Yes | |
On schedule | Yes | |
Max occupancy | Yes | |
Global antipassback | Yes | |
First-person-in rule | ||
Enforce on door unlock schedule | Yes | |
Enforce on access rules | Yes | |
Elevator control | Elevators | Not applicable |
Zone management | I/O zone | No |
Hardware zone | No |
1
The Reader buzzer
behavior options are not supported.
2 Update depends on Polling
interval (v3 locks) or Status report
interval (locks other than v3 locks).
4
The Synergis unit must be connected to the Access
Manager.
5 Throwing the deadbolt doesn't act as privacy mode.
6 When the
deadbolt is thrown during an unlock schedule, then the door locks as expected.
However, when the deadbolt is retracted during the unlock schedule, the door
doesn't unlock.
7 Not all Aperio-enabled locks support the key override sensor.
Confirm with the manufacturer to know the exact sensors that are supported for
each model.
8
Not recommended for
Card-In/REX-Out doors because a cardholder's presence in the area cannot be
verified.