Supported secure I/O module features in Synergis Softwire 11.5.3 - Synergis Softwire 11.5.3

Synergis™ Softwire Integration Guide 11.5.3

Product
Synergis Softwire
Content type
Guides > Integration guides
Version
11.5
Release
11.5.3
ft:locale
en-US
Last updated
2025-01-23

Interface modules come in all shapes and sizes and offer a wide range of features. Synergis™ Softwire supports most of the common features found on the market.

Synergis Softwire 11.5.3 supports the following secure I/O module features.
The following is the legend for some common values found in the Supported column:
Yes
Synergis Softwire supports the feature and the interface module offers it.
No
Synergis Softwire does not support the feature, but the interface module offers it.
Not applicable
The interface module does not offer the feature.
Features Supported
General characteristics  
Category of interface module I/O module
Communication protocol RS-485
Encrypted communication Yes
Scalability  
Maximum number of interface modules per Synergis unit RS-485 channel 161
Recommended maximum number of interface modules per Synergis unit 32

1 Having many interface modules per channel decreases the polling rate per interface. This is a consideration if you have PIN readers connected to the same channel in daisy chain. If the readers are configured to output PIN in 4-bit Burst Keypad Mode, decreasing the polling rate per interface might increase the chance of a digit being missed when someone enters their PIN quickly, resulting in a denied access.