You must enable primitive rules on every Synergis™ unit that controls a door entity producing outputs for specific door events.

What you should know

If the Synergis™ unit is disconnected from its Access Manager, the primitive rules are still applied.

Procedure

  1. Activate the feature using the following URL:
    https://<IP address>/Features/DuiPrimitiveRules/Enabled/Set?value=true
    NOTE: <IP address> is the IP address of your Synergis™ unit.
  2. Validate that the feature is enabled:
    1. From the Config Tool home page, open the Access control task, and click the Roles and units view.
    2. Select the Synergis™ unit from the entity tree.
      The Primitive rules tab is visible on the Hardware page of the unit.
    If the unit was already selected, click on a different entity in the entity tree, and then reselect the unit to refresh the Hardware page.
  3. (Optional) Deactivate the feature using the following URL:
    https://<IP address>/Features/DuiPrimitiveRules/Enabled/Set?value=false