Resolved issues are software issues from previous releases that have been fixed in the current release.

Interface module Issue Description
Mercury 2242451 Mercury FICAM deployments: When you remove an unlock schedule from a door, the door does not relock.
Mercury 2203476 When using a custom Wiegand format to trim down card reads, offline reads and Card and PIN functionality for cards with the same bit length as the custom format stop working.
Mercury 1958812 Mercury EP: If no access rule is assigned to the door, presenting a credential to a reader in Card and PIN mode will cause an Access denied: Card and PIN timeout event instead of an Access denied: No access rule assigned event.
Mercury 1756814 Mercury EP: Maximum PIN length defaults to six instead of matching the unit-wide setting.
Synergis™ IX 2344717 When Operator Timeout is enabled on the Synergis™ IX unit's web page, the unit goes offline for a few second at each configured Operator Timeout interval.
Synergis™ IX 2111908 Synergis™ IX controller low-battery and power-loss events do not trigger warnings in Security Center.
Synergis™ IX 2047495 If a cardholder enters a duress PIN while Synergis™ Softwire is restarting or while the Synergis™ IX controller is disconnected from the network, the logged duress event does not include cardholder information.