The following software issues are resolved in Synergis™ Softwire 11.2.1.
Interface module | Issue | Description |
---|---|---|
All | 2873657 | The people count is not always updated when cardholder movement is generated from Entry assumed events. |
Assa Abloy IP | 2902693 | SARGENT locks: When passage mode is enabled per access rule and doors are configured with an unlock schedule, locks might be in an incorrect state after a hardware configuration change or a Synergis™ Softwire restart. |
Mercury | 2921023 | When Mercury offline decision mode is enabled, Access granted events are not seen in the Monitoring task if the door does not have a door sensor. |
Mercury | 2861879 | In Synergis™ Softwire 11.1 and 11.2, long credential formats configured on the Mercury controller settings page of the Synergis™ Appliance Portal might not work correctly. |
Mercury | 2835812 | The FICAM database layout has an incorrect maximum supported credential size of 160 bits for LP1501, LP1502, LP2500, and LP4502 controllers, instead of 200 bits like other Mercury controllers. |
Synergis™ IX | 2941523 | The default Master and Installer cardholders have access to intrusion keypads. |
Synergis™ IX | 2934267 | Synergis™ Softwire CardFormatAutoConfig is disabled by default, causing incorrect card reads unless the card format is manually selected per reader type in the Synergis™ IX Portal. |
Synergis™ IX | 2911325 | The command to restart the module uses the wrong parameter to identify the module, which might cause a high number of events in the Intrusion Manager database. |
Synergis™ IX | 2884437 | Setting a door in maintenance mode might cause a mismatch between the physical state of the door lock and reported state of door lock in Security Center. |
Synergis™ IX | 2862467 | Wiegand readers connected to reader expanders report tamper events, even though they are configured not to. |
Synergis™ IX | 2835792 | Wiegand readers in Synergis™ IX go offline after two minutes if there is no card activity. |