Synergis™ Softwire 11.3.2 includes the following known issues.
Interface module | Issue | First reported in | Description |
---|---|---|---|
Assa Abloy IP | 956660 | 10.5 GA | When opening a door that has an assigned door sensor, no Entry detected or Entry assumed events are generated. |
Assa Abloy IP | 756219 | 10.4 GA | Cx-type locks: When a passage mode-enabled door is unlocked, it does not relock when security clearance is applied through threat level. |
Axis | 691063 | 10.4 GA | Axis A1001: If the Door forced option is disabled and the Axis controller is disconnected from the Synergis™ unit, the card reader still beeps when the door is forced open. |
BEST Wi-Q | 3074763 | 11.3.1 | When passage mode is enabled, Door forced open events are generated
every time the door is open. Workaround: Disable Door forced open
events in Security
Desk if passage
mode is enabled.
|
Mercury | 2964481 | 11.2.1 | After upgrading to 11.2.1 or later, Mercury OSDPv2 readers set to secure mode
enrolled with Synergis™
Softwire 11.1 or 11.2.0 and
Security Center 5.10.1.0 or later must be
paired again. Workaround: For more information, see KBA-79088.
|
Mercury | 2760561 | 11.2.0 | Card reads are delayed or misread on MR62e boards when decreasing the number of
assigned readers to logical entities. Workaround: Use the following URL:
https://[SCL IP
address]/MercuryEP/Bus/[guid]/DespecifyAllOsdpReaders.
|
Mercury | 2355360 | 10.11 GA | When a Mercury controller reconnects to the Synergis™ unit, offline events that should be logged as Access denied: Denied by access rule are logged as Access Denied: Out of schedule instead. |
Mercury | 2222290 | 10.10 GA | When the two-person rule is in effect, a door set to either TurnstileMercury1 or TurnstileMercury2 only unlocks after every second badge. |
RIO | 2315828 | 10.11 GA | If the bus name includes spaces and ends with repeating characters, the bus
cannot be accessed. Workaround: Do not include spaces in device
names.
|
SimonsVoss | 3021679 | 11.3.0 | It is possible to get a Mechanical Key Override - Inactive event in
Security Center, even though SimonsVoss
locks do not have key overrides. Workaround: Disregard this
event.
|
Synergis™ IX | 2354370 | 10.11 GA | On the Synergis™ IX unit's web page, changing the Module Type or Module Input values of Trouble Inputs might break functionality. |
Synergis™ IX | 2243787 | 10.11 GA | Synergis™ IX input configuration is not
displayed or managed in Config
Tool. Workaround: Configure the input settings from the Synergis™ IX unit's web page.
|
Synergis™ IX | 2122008 | 10.11 GA | Intrusion detection area alarms must be acknowledged from the keypad of the Synergis™ IX unit, instead of from Security Desk. |
Synergis™ IX | 2158297 | 10.10 GA | When a cardholder enters a duress PIN into a Synergis™ IX intrusion keypad, the triggered duress event lacks the cardholder information. |
Synergis™ IX | 2100411 | 10.10 GA | When a door in an interlocked area denies REX or manual unlocks from Security Center due to another door being open, the reason is listed in the Synergis™ IX controller portal, but not in Security Center. |