Known issues in Synergis Softwire 11.4.1 - Synergis Softwire 11.4.1

Synergis™ Softwire Release Notes 11.4.1

Applies to
Synergis Softwire 11.4.1
Last updated
2023-05-03
Content type
Release notes
Language
English
Product
Synergis Softwire
Version
11.4

Synergis™ Softwire 11.4.1 includes the following known issues.

Interface module Issue First reported in Description
All 3164681 11.4.0 Enrolling a Synergis Cloud Link unit with IPv6 while peer-to-peer is enabled on the Access Manager prevents its peers to connect to it.
Assa Abloy IP 956660 10.5 GA When opening a door that has an assigned door sensor, no Entry detected or Entry assumed events are generated.
Assa Abloy IP 756219 10.4 GA Cx-type locks: When a passage mode-enabled door is unlocked, it does not relock when security clearance is applied through threat level.
Axis 3343711 11.4.0 Upgrading the Axis controller firmware from Config Tool shows that the upgrade failed even though it succeeded.
Axis 3188315 11.4.0 Incorrect Door locked event timestamp when the door is configured to lock immediately after it opens. The door is locked at the right time, but the timestamp shows that it is locked only when the door closes.
Axis 691063 10.4 GA AXIS A1001: If the Door forced option is disabled and the Axis controller is disconnected from the Synergis™ unit, the card reader still beeps when the door is forced open.
BEST Wi-Q 3074763 11.3.1 When passage mode is enabled, Door forced open events are generated every time the door is open.
Workaround: Disable Door forced open events in Security Desk if passage mode is enabled.
Mercury 3337558 11.4.0 When a door is configured to relock after X seconds, the Door locked event timestamp indicates when the door was opened, not when it physically relocked.
Mercury 3333713 11.4.0 Mercury LP controllers connected to Legacy Synergis Cloud Link units are not reconnecting following disconnections after 24 days of uptime.
Workaround: Restart Synergis Softwire.
Mercury 2964481 11.2.1 After upgrading to 11.2.1 or later, Mercury OSDPv2 readers set to secure mode enrolled with Synergis Softwire 11.1 or 11.2.0 and Security Center 5.10.1.0 or later must be paired again.
Workaround: For more information, see KBA-7908.
Mercury 2760561 11.2.0 Card reads are delayed or misread on MR62e boards when decreasing the number of assigned readers to logical entities.
Workaround: Use the following URL: https://[SCL IP address]/MercuryEP/Bus/[guid]/DespecifyAllOsdpReaders.
Mercury 2355360 10.11 GA When a Mercury controller reconnects to the Synergis unit, offline events that should be logged as Access denied: Denied by access rule are logged as Access Denied: Out of schedule instead.
Mercury 2222290 10.10 GA When the two-person rule is in effect, a door set to either TurnstileMercury1 or TurnstileMercury2 only unlocks after every second badge.
RIO 2315828 10.11 GA If the bus name includes spaces and ends with repeating characters, the bus cannot be accessed.
Workaround: Do not include spaces in device names.
SALLIS 3224198 11.3.4 Double-badge activation does not work with the SALTO SALLIS integration in Synergis Softwire 11.3 and 11.4.
Workaround: Override the unlock schedule, and then cancel the override. The lock will be in access control mode if no unlock schedule is active.
SimonsVoss 3021679 11.3.0 It is possible to get a Mechanical Key Override - Inactive event in Security Center, even though SimonsVoss locks do not have key overrides.
Workaround: Disregard this event.
Synergis IX 3225426 11.4.0 The reader LED flashes continuously if the wrong I/O is associated to the wrong reader.
Workaround: Use the following wiring:
  • Door 1 must use the reader port 1 and output 1 as the door lock, and inputs 1 - 4 for REX and door sensor.
  • Door 2 must use the reader port 2 and output 2 as the door lock, and inputs 5 - 8 for REX and door sensor.
Synergis IX 2354370 10.11 GA On the Synergis IX unit's web page, changing the Module Type or Module Input values of Trouble Inputs might break functionality.
Synergis IX 2243787 10.11 GA Synergis IX input configuration is not displayed or managed in Config Tool.
Workaround: Configure the input settings from the Synergis IX unit's web page.
Synergis IX 2158297 10.10 GA When a cardholder enters a duress PIN into a Synergis IX intrusion keypad, the triggered duress event lacks the cardholder information.
Synergis IX 2122008 10.11 GA Intrusion detection area alarms must be acknowledged from the keypad of the Synergis IX unit, instead of from Security Desk.
Synergis™ IX 3087030 11.3.4 Creating an intrusion area on Synergis IX units causes the unit to go offline for several seconds.