Synergis™ Softwire 11.4.1 includes the following known issues.
Interface module | Issue | First reported in | Description |
---|---|---|---|
All | 3164681 | 11.4.0 | Enrolling a Synergis Cloud Link unit with IPv6 while peer-to-peer is enabled on the Access Manager prevents its peers to connect to it. |
Assa Abloy IP | 956660 | 10.5 GA | When opening a door that has an assigned door sensor, no Entry detected or Entry assumed events are generated. |
Assa Abloy IP | 756219 | 10.4 GA | Cx-type locks: When a passage mode-enabled door is unlocked, it does not relock when security clearance is applied through threat level. |
Axis | 3343711 | 11.4.0 | Upgrading the Axis controller firmware from Config Tool shows that the upgrade failed even though it succeeded. |
Axis | 3188315 | 11.4.0 | Incorrect Door locked event timestamp when the door is configured to lock immediately after it opens. The door is locked at the right time, but the timestamp shows that it is locked only when the door closes. |
Axis | 691063 | 10.4 GA | AXIS A1001: If the Door forced option is disabled and the Axis controller is disconnected from the Synergis™ unit, the card reader still beeps when the door is forced open. |
BEST Wi-Q | 3074763 | 11.3.1 | When passage mode is enabled, Door forced open events are generated
every time the door is open. Workaround: Disable Door forced open
events in Security Desk if passage mode is enabled.
|
Mercury | 3337558 | 11.4.0 | When a door is configured to relock after X seconds, the Door locked event timestamp indicates when the door was opened, not when it physically relocked. |
Mercury | 3333713 | 11.4.0 | Mercury LP controllers connected to Legacy Synergis Cloud Link units are not
reconnecting following disconnections after 24 days of uptime. Workaround: Restart Synergis Softwire.
|
Mercury | 2964481 | 11.2.1 | After upgrading to 11.2.1 or later, Mercury OSDPv2 readers set to secure mode
enrolled with Synergis Softwire 11.1 or 11.2.0 and Security Center 5.10.1.0 or later
must be paired again. Workaround: For more information, see
KBA-7908.
|
Mercury | 2760561 | 11.2.0 | Card reads are delayed or misread on MR62e boards when decreasing the number of
assigned readers to logical entities. Workaround: Use the following URL:
https://[SCL IP
address]/MercuryEP/Bus/[guid]/DespecifyAllOsdpReaders.
|
Mercury | 2355360 | 10.11 GA | When a Mercury controller reconnects to the Synergis unit, offline events that should be logged as Access denied: Denied by access rule are logged as Access Denied: Out of schedule instead. |
Mercury | 2222290 | 10.10 GA | When the two-person rule is in effect, a door set to either TurnstileMercury1 or TurnstileMercury2 only unlocks after every second badge. |
RIO | 2315828 | 10.11 GA | If the bus name includes spaces and ends with repeating characters, the bus
cannot be accessed. Workaround: Do not include spaces in device
names.
|
SALLIS | 3224198 | 11.3.4 | Double-badge activation does not work with the SALTO SALLIS integration in
Synergis Softwire 11.3 and 11.4. Workaround: Override the unlock schedule,
and then cancel the override. The lock will be in access control mode if no unlock
schedule is active.
|
SimonsVoss | 3021679 | 11.3.0 | It is possible to get a Mechanical Key Override - Inactive event in
Security Center, even though SimonsVoss locks do not have key overrides. Workaround: Disregard this event.
|
Synergis IX | 3225426 | 11.4.0 | The reader LED flashes continuously if the wrong I/O is associated to the wrong
reader. Workaround: Use the following wiring:
|
Synergis IX | 2354370 | 10.11 GA | On the Synergis IX unit's web page, changing the Module Type or Module Input values of Trouble Inputs might break functionality. |
Synergis IX | 2243787 | 10.11 GA | Synergis IX input configuration is not displayed or managed in Config
Tool. Workaround: Configure the input settings from the Synergis IX
unit's web page.
|
Synergis IX | 2158297 | 10.10 GA | When a cardholder enters a duress PIN into a Synergis IX intrusion keypad, the triggered duress event lacks the cardholder information. |
Synergis IX | 2122008 | 10.11 GA | Intrusion detection area alarms must be acknowledged from the keypad of the Synergis IX unit, instead of from Security Desk. |
Synergis™ IX | 3087030 | 11.3.4 | Creating an intrusion area on Synergis IX units causes the unit to go offline for several seconds. |