All 3622092 Synergis™ units enrolled in hosted Synergis™ SaaS edition deployments: When a supervised onboard I/O is configured on the Synergis unit, an offline Input active event is wrongly generated after the unit restarts.
All 3524860 Offline Door open too long events are missing after Synergis Softwire restarts.
Axis 34229781 When the alarm option for Door forced open is set to Suppressed when door closes, the alarm continues after the door is closed.
Mercury 3482147 When the Mercury event buffer is exceeded and offline events are lost, you are not notified.
Mercury 3481834 After upgrading Synergis Softwire from 11.3 to 11.4, Access granted events that occurred offline are reported with empty credentials.
Mercury 3481354 When a door is held or forced open while the Mercury controller is in offline mode, reader LED trigger events consume a large percentage of the offline events that can be stored on the controller.
Mercury 3481353 When adding or updating the configuration of a door controlled by a Mercury controller, the configuration sometimes gets applied to the wrong door.
Mercury 3473888 According Mercury's visitor escort behavior, any cardholder in the visitor's designated escort group can act as an escort, regardless of whether or not the cardholder has the Can escort visitors option on in Security Center.
Mercury 3470095 Sometimes, when the connection between the Synergis™ Cloud Link and the Mercury controller is unstable, the Synergis Cloud Link can get stuck in a restart loop, causing doors to fail to operate.
Mercury 3427319 When the door setting Disable host decision handoff (offline mode) is enabled, the Access Manager role disconnects from the Mercury controller if the latter grants access to a credential that has just been removed from the system, but has not yet synced with the controller.
STid 3472263 With a STid reader operating in transparent mode, when the card has random UID enabled and the application uses diversified keys, the authentication fails.
Synergis IX 3513567 When modifying a door's properties, the reader type assigned to that door changes.
Synergis IX 3476344 When the Lock out REX when inside area armed option is enabled, REX events are still generated in Security Center when REX is triggered.
Synergis IX 3470027 Synergis IX expander modules appear as offline in Config Tool after upgrading to Synergis Softwire 11.4.2.
Synergis IX 3469449 The Hardware page in the Synergis Appliance Portal is not accessible after upgrading to Synergis Softwire 11.4.2 with at least one Synergis IX unit enrolled.