The ThyssenKrupp plugin 3.1 includes the following known issues.
Issue | Description |
---|---|
2811297 | This plugin does not support the 32-bit CSN card format. Supported formats are:
|
1788036 | Cameras cannot be associated to elevators. |
1770588 | In System messages, clicking to see more information about DED warnings opens a window that displays information about security profiles instead of about why the DED is in warning state. |
1759564 | From the plugin's Configuration page, if you want to skip
a landing when manually adding landings to an elevator group, you must add the
landing, and then delete it from the entity tree. For example, if you want to create Landing 1.1F and Landing 1.3F but not Landing 1.2F, you must add Landing 1.1F, 1.2F, and 1.3F, and then delete Landing 1.2F. Workaround: Use
the auto-discovery feature instead of manually creating each
entity.
|
1752933 | Entity state colors in the entity tree of the plugin might be misleading. DEDs can turn yellow even if they are online. |
1749861 | If you disable an elevator group in the ThyssenKrupp system, the elevators in that group are still displayed as online in Security Center. |