For Security Center to communicate with a Traka system, you must provide the URL of the Traka Integration Engine and specify
the communications ports.
Procedure
-
In Config Tool, open the Traka Asset Management plugin role.
-
In the Plugins task, select the plugin role from the
entity browser, and click the Properties tab.
-
Configure the following:
- URL
- The Web address for the Traka Integration Engine. This URL contains the host name
or IP address of the computer that hosts the Traka Integration Engine Service and
the communication port number. The default port number is 10700. Example:
https://MyTrakaServerHostname:10700/
NOTE: Only IP addresses
that the plugin can resolve to a hostname by the DNS will work. IP adresses can
only be used as of plugin version 3.3.0.
- Events port
- The port number used by the Traka Integration Engine Service to send events over
the IP network. This port number is different from the port referred to in the URL.
The default is 10800.
- Time zone
- The time zone from which Security Center receives events. This must match the time
zone setting of the system that is running the Traka Integration Engine Service.
NOTE: By default, the time zone is set to match the directory server.
-
Click Apply.
-
Click Test connection to confirm that
the plugin role can communicate with the Traka Integration Engine.
-
If you get a message that the plugin is unable to communicate with the Traka Integration Engine, do the following:
-
Deactivate the plugin role.
-
Activate the plugin role.
-
Wait a few minutes, then test the connection again.