To bypass arm an intrusion detection area in Security Center, you must enable the proper settings on the panel, using the ATS8500 Standalone Downloader.

What you should know

For more information about arming commands in Security Center, see Intrusion detection area widget.

Procedure

  1. In ATS8500 Standalone Downloader, select the panel you want to configure.
  2. In Panel > Set Options, set the Forced set option to On.

Results

You can now use the bypass arm command on the intrusion detection area associated to this panel in Security Center.