To be able to use an intrusion panel in Security Center, you must create the panel as an intrusion
detection unit entity in Config
Tool.
Procedure
-
From the Config
Tool home page,
open the Intrusion detection task.
-
From the entity browser, select the Intrusion Manager role that will manage the
intrusion panel.
-
Under the entity browser, click Intrusion detection unit ().
-
From the Unit type drop-down list in the Manual
add dialog box, select SPC.
-
Enter the IP address of the intrusion panel.
-
In the Port field, select the port number configured in the
panel.
50000 is the default value.
-
In the Listener section, configure the following settings:
- Network card
- The Genetecâ„¢
Server network card used to
communicate with SPC intrusion panels.
- Port
- The Genetecâ„¢
Server TCP port used for SPC
panel connections.
NOTE: Refer to the FlexC and ATS configuration
in the SPC Pro
application.
-
In the User information section, enter the following
credentials:
- Username
- The name of the SPC panel user to connect the panel.
- PIN
- The PIN you configured on the panel for the selected user.
-
Select the Enroll disconnected unit check box to enroll the SPC
intrusion panel, even if it is not yet physically connected.
-
Click Add and close.
Results
The intrusion detection unit is displayed under the Intrusion Manager role in the
entity browser. After the unit is connected, the Intrusion Manager automatically creates the intrusion
detection areas, outputs and inputs (zones) that are configured on the panel.