Connecting Security Center to the Schindler PORT system - Schindler Port Elevator 3.0

Schindler PORT Elevator Plugin Guide 3.0

Applies to
Schindler Port Elevator 3.0
Last updated
2022-09-23
Content type
Guides
Guides > Plugin and extension guides
Language
English
Product
Schindler Port Elevator
Version
3.0

To receive information from the Schindler PORT elevator system in Security Center, you must enable communication between the two systems.

Procedure

  1. From the Config Tool home page, open the Plugins task.
  2. Select the elevator system from the entity browser, and click the Properties tab.
  3. In the Interfaces section, configure the following:
    Database
    The IP address and port number of the Schindler PORT database. This information is required to push Security Center cardholder information into the Schindler PORT system.
    Primary call
    The IP address and port number of the Schindler PORT call interface that receives elevator requests from Security Center. This information is required to dispatch elevators. If necessary, a secondary call address can also be added.
    Reporting
    The IP address and port number of the Schindler PORT interface that Security Center uses to listen to events coming from the Schindler PORT system. This information is required to generate reports.
  4. (Optional) To enable Synergis™ readers for use with Schindler PORT zones and terminals, switch the Synergis integration option to ON.
  5. Click Apply.

Results

The elevators from the Schindler PORT elevator system are added to the entity browser.