[KBA-01314] Archiver statistics show incorrect camera details

This article explains why camera statistics might not update properly when refreshed from within the Archiver Statistics window.

Summary

Under the Resources tab in the Archiver role, users can click Statistics to see statistics for all the entities on the Archiver. However, sometimes the camera statistics might not update properly even if the other various stats do.

More Information

To resolve this issue:

  1. Select Archiver > Resources > Advanced Settings > Additional Settings.
  2. Click +.
  3. In the Name field, enter EncodersBitrateCalculationFix.