Report pane columns for the Alarm report task - Security Center 5.6

Security Center User Guide 5.6

series
Security Center 5.6
revised_modified
2019-10-09

After generating a report, the results of your query are listed in the report pane. This section lists the columns available for the relevant reporting task.

NOTE: If you generated the Alarm report using Web Client, not all of the report columns are available.
Acknowledged by
User who acknowledged the alarm. When the alarm is acknowledge automatically by the system, Service is indicated.
Acknowledged on
Time the alarm was acknowledged.
Alarm
Alarm entity name.
Alarm color
Color of the alarm.
Custom fields
The pre-defined custom fields for the entity. The columns only appear if custom fields are defined for the entity, and if the custom fields were made visible to you when they were created or last configured.
External instance ID
Only for federated alarms. The original alarm instance ID on the federated system.
ID
Alarm instance number. Uniquely identifies each alarm instance.
Investigated by
The user who put the alarm into the under investigation state.
Investigated on
The timestamp when the alarm was put into the investigation state.
Occurrence period
Period when the event occurred.
Priority
Alarm priority. All alarms imported from Omnicast have their priority set to 1 by default. You can change their priority at a later time in the Config Tool.
Source
The source entity that triggered the alarm, when the alarm is triggered by an event-to-action. It shows a username when the alarm is triggered manually.
Source time
Time of the alarm-triggering event. The only time Source time and Triggering time are different is when the event occurred while the access control unit was offline.
State
Current state of the alarm.
Active
Alarm is not yet acknowledged. Selecting an active alarm shows the alarm acknowledge buttons in the report pane.
Acknowledged (Default)
Alarm was acknowledged using the default mode.
Acknowledged (Alternate)
Alarm was acknowledged using the alternate mode.
Acknowledged (Forcibly)
Alarm was forced to be acknowledged by an administrator.
Under investigation
Alarm with an acknowledgement condition that is still active was put under investigation..
Acknowledgement required
Alarm with an acknowledgement condition that was cleared is ready to be acknowledged.
Triggering event
Event that triggered the alarm (if triggered through an event-to-action). Manual action is indicated when the alarm was manually triggered by a user.
Trigger time
Time the alarm was triggered in Security Center.