[KBA-00967] Bosch Autodome Easy II digital input pins trigger incorrectly in Omnicast™

This article explains why both digital input pins on a Bosch Autodome Easy II are initiated in Omnicast™ even though only one input pin was triggered.

Symptoms

When triggering or closing a single line-in contact on a Bosch Autodome Easy II, its web interface correctly displays one digital input as being triggered. However, the Archiver states that both contacts (Ln-In 1 & 2) have been initiated, which is incorrect.

Cause

BICOM notifications are not properly handled by the Archiver.

Workaround

None.

Status

A hotfix is available for Omnicast™ 4.7 SR1 (HF1208). Contact the Genetec™ Technical Assistance Center to obtain it.