[KBA-00995] Custom Application Terminates Unexpectedly when Using the Omnicast 4.8 SR1 SDK

This article explains why a custom application that connects to Omnicast 4.8 SR1 using the SDK might close unexpectedly.

Symptoms

A custom application closes unexpectedly when using the Omnicast 4.8 SR1 SDK to view video from an Omnicast system.

Cause

The Omnicast 4.8 SR1 SDK version will always reserve the maximum amount of memory for each camera being displayed. The memory usage will then increase rapidly and the custom application will eventually become unstable and terminate unexpectedly

Workaround

Install the Omnicast 4.8GA SDK.