Supported OSDP readers in Synergis™ Softwire 10.11 - Synergis™ Softwire 10.11

Synergis™ Softwire Integration Guide 10.11

series
Synergis™ Softwire 10.11
revised_modified
2020-06-26

With Secure Open Supervised Device Protocol (OSDP), you can move away from Wiegand readers without making a large infrastructure investment, because only the readers need to be replaced.

The following OSDP readers were certified and are supported by Synergis™ Softwire 10.11. These readers were tested for use with random-key encrypted communication; other OSDP-compliant readers should also work correctly.
Manufacturer Model Certified firmware
Allegion
  • aptiQ/Schalge MT15-485 X14_14 reader
FW1212
HID
  • HID Global iCLASS SE R10 (900, OSDP)
  • HID Global iCLASS SE R15 (910, OSDP)
  • HID Global iCLASS SE R40 (920, OSDP)
  • HID Global iCLASS SE RK40 (921, OSDP)
  • HID Global iCLASS SE Decor (R95A, OSDP)
00312-F, 00316-F
STid
  • ARC-A, OSDP version (ARC-W33-A/PH5-7OS/1)
  • ARC-B, OSDP version (ARC-W33-B/PH5-7OS/1)
  • ARC1, OSDP version (ARC1-W33-X/PH5-7OS/1)
v07

Supported Synergis™ appliances

OSDP readers connect directly to the RS-485 ports on a Synergis™ Cloud Link or a Synergis™ Master Controller equipped with an RS-485 board.

Streamvault™ appliances are not equipped with RS-485 ports, and are therefore not compatible with direct OSDP readers.

Wiring instructions for STid readers

To enable the extended features of the RS-485 bus, physically place 1.5k Ohm resistors (R1 and R2) on the GND and Vcc connectors of the reader. These 1.5k Ohm resistors do not come with the STid units.