Supported Synergis™ appliance features for Axis controller integration with Synergis™ Softwire 10.11 - Synergis™ Softwire 10.11

Synergis™ Softwire Integration Guide 10.11

series
Synergis™ Softwire 10.11
revised_modified
2020-06-26

Not all Synergis™ appliance features are supported with the integration of Axis controllers.

The Axis controller integration supports the following Synergis™ Appliance Portal and Synergis™ Softwire features. For a description of these features, see Interface tour of the Synergis™ Appliance Portal.
Synergis™ Appliance Portal and firmware features Supported
Hardware configuration (pre-staging capability)  
Manual enrollment (Add hardware dialog box) Yes
Automatic enrollment (Scan button) No
Property configuration Yes
Configuration cloning (Clone button) Yes
I/O diagnostics (live monitoring of inputs, relays, and readers) Yes
Interface module firmware display Yes
Interface module firmware upgrade (apply recommended firmware) Manual1
Double-badge activation Online
Access control behavior (Synergis™ unit-wide settings)2  
Lock relay (After door opens or When door closes) Yes
Interlock setting (Single door unlock or Single door open) Online
Do not generate Door open too long events when door is unrestricted Yes
Reader setting (Card or PIN or Card only) Yes
Maximum PIN length in digits4 16
Degraded mode settings Not applicable

1 The recommended Axis firmware must be uploaded to the Synergis™ appliance by applying the file Axis_10.11_xxx.y.sfx as a firmware upgrade through Synergis™ Appliance Portal.

2 The door behavior settings are overwritten by the individual door settings configured in Security Center.

4 For interface modules that support HID mode-00 readers.