The door modes supported by Allegion Schlage LE locks over IP suit a wide selection of access-control contexts.

Requirements

The minimum required Synergis™ appliance firmware is 10.10 GA. LE locks are supported as of Security Center 5.7 SR5.

The modes and their functions

The supported door modes are configured through the Door mode numeric custom field on the door in Config Tool. The modes are:

  • 0 - Normal operation
  • 1 - Classroom: this mode is not supported
  • 2 - Office: press button to unlock and relock
  • 3 - Privacy: press button to deny all access from outside, press button or REX out to deactivate
  • 4 - Apartment: press button or REX out to unlock, stays unlocked until button press or swipe to relock