Enabling CCURE alarm acknowledgment and door actions in Security Desk - Security Center | CCURE

Enabling CCURE alarm acknowledgment and door actions in Security Desk

series
Security Center | CCURE
revised_modified
2018-01-31

To be able to unlock CCURE doors, and acknowledge CCURE alarms from Security Desk you must add an entry in the Genetec.Plugins.CCure.AccessControl.Client.dll.config file.

What you should know

The minimum version required is CCURE_3.3.243.0 which is compatible with CCURE 9000 systems 2.30, 2.40, 2.50, and 2.60.

Procedure

  1. Log on to the Security Center Directory server.
  2. Browse to the following folder C:\Program Files (x86)\Security Center Plugins\CCure\Genetec.Plugins.CCure.AccessControl.Client.dll.config
  3. Open the Genetec.Plugins.CCure.AccessControl.Client.dll.config file in a text editor.
  4. In the file, set the action enable option to true, by adding the following entry: <ActionEnabled="true">.
    <CCureAccessControlClient ConnectionRetryInterval="5" PingInterval="60" PingTimeout="5" CardholderGuid="true" ActionEnabled="true"/>
  5. Save the file, and then close it.
    You can now lock and unlock doors using the door widget, and acknowledge alarms through the monitoring task in Security Desk..