Creating the intrusion detection unit for SPC integration - SPC intrusion panel 3.1

Vanderbilt SPC Intrusion Panel Extension Guide 3.1

Applies to
SPC intrusion panel 3.1
Last updated
2023-07-20
Content type
Guides > Plugin and extension guides
Language
English
Product
SPC intrusion panel
Version
3.1

To be able to use an intrusion panel in Security Center, you must create the panel as an intrusion detection unit entity in Config Tool.

Procedure

  1. From the Config Tool home page, open the Intrusion detection task.
  2. From the entity browser, select the Intrusion Manager role that will manage the intrusion panel.
  3. Under the entity browser, click Intrusion detection unit ().
  4. From the Unit type drop-down list in the Manual add dialog box, select SPC.
  5. Enter the IP address of the intrusion panel.
  6. In the Port field, select the port number configured in the panel.
    50000 is the default value.
  7. In the Listener section, configure the following settings:
    Network card
    The Genetecâ„¢ Server network card used to communicate with SPC intrusion panels.
    Port
    The Genetecâ„¢ Server TCP port used for SPC panel connections.
    NOTE: Refer to the FlexC and ATS configuration in the SPC Pro application.
  8. In the User information section, enter the following credentials:
    Username
    The name of the SPC panel user to connect the panel.
    PIN
    The PIN you configured on the panel for the selected user.
  9. Select the Enroll disconnected unit check box to enroll the SPC intrusion panel, even if it is not yet physically connected.
  10. Click Add and close.

Results

The intrusion detection unit is displayed under the Intrusion Manager role in the entity browser. After the unit is connected, the Intrusion Manager automatically creates the intrusion detection areas, outputs and inputs (zones) that are configured on the panel.