Adding Collins Aerospace radars as tracking systems to Security Center - Restricted Security Area Surveillance 3.2

Restricted Security Area Surveillance Plugin Guide 3.2

series
Restricted Security Area Surveillance 3.2
revised_modified
2019-04-02

To monitor the restricted areas secured by your tracking system in Security Center, you must add the Collins Aerospace server as a tracking system entity using Config Tool.

Before you begin

  • Confirm that the tracking system and its radars are configured and functioning properly.
  • (Optional) Position the cameras for each zone so that they have a view of the restricted area and make sure that the cameras are functioning properly.
  • (Optional) Add custom events in Security Center.
  • Add a geo-referenced map to Security Center. For more information about creating maps, refer to the Security Center Administrator Guide.
  • Ensure that a sufficient number of radar licenses is available.

What you should know

By default, PSR-500 server communicates over TCP/IP port 80.

Procedure

  1. From the Config Tool home page, open the Area view task.
  2. Click Add an entity (), and then select Tracking system.
  3. On the Tracking system information page of the wizard, enter the following information:
    Type
    Select PSR-500.
    Name
    Enter a unique name for this tracking system.
  4. On the Communication page, enter the following information:
    IP address
    Enter the IP address of the server that connects to the tracking devices.
    Port
    The TCP/IP port that the plugin and the tracking system uses to communicate.
    User and Password
    The administrator-level credentials required to log on to the tracking system's software.
  5. Click Refresh () to connect.
  6. When the connection is Online, click Next page ().
  7. On the RSA configuration page, enter the following information:
    Import on map
    Select the map that you want to use to display the devices in Security Center.
    Auto tracking
    When set to ON , PTZ cameras associated with the zones automatically follow a target as it moves.
    Events
    Map the incoming events from the device to custom events in Security Center. Click Add (), then select a desired event in the RSA event column and a corresponding event in the Custom event column.
  8. Click Finish.
    The system and its devices are listed in the Area view entity tree.

After you finish