Adding Sensurity perimeter intrusion detection systems as tracking systems to Security Center - Restricted Security Area Surveillance 3.5

Restricted Security Area Surveillance Plugin Guide 3.5

series
Restricted Security Area Surveillance 3.5
revised_modified
2020-08-27

To monitor your Sensurity system in Security Center, you must add the Sensurity system as a tracking system entity in Config Tool.

Before you begin

  • Confirm that the tracking system and its tracking devices are configured and functioning properly.
  • Confirm that the plugin role is configured and communicating with the tracking system.
  • (Optional) Add custom events in Security Center.
  • Create a georeferenced map in Security Center.

    For more information, see the Security Center Administrator Guide.

  • Ensure that a sufficient number of perimeter system licenses is available from Restricted Security Area Surveillance role > Properties > Licenses.

Procedure

  1. From the Config Tool home page, open the Area view task.
  2. Click Add an entity (), and then select Tracking system.
  3. On the Tracking system information page of the wizard, enter the following information:
    Type
    Select Sensurity.
    Name
    Enter a unique name for this tracking system.
  4. On the Communication page, enter the following information:
    IP address
    The IP address of the server that hosts the Sensurity Universe Service.
    Port
    The TCP/IP port that the plugin and the Sensurity Universe Service use to communicate.
    Password
    The administrator-level password required to log on to the tracking system's software.
  5. Click Refresh connection status () to connect.
  6. (Optional) Click Get config () to display the information about the Sensurity Universe Service.
  7. On the Specific configuration page, do the following:
    1. Click Add a sensor ().
      Each sensor consists of a transmitter and a receiver.
    1. In the Transmitter list, select a device.
    2. In the Receiver list, select a device.
    3. In the Auto acknowledge alarm time field, specify the amount of time RSA will wait before acknowledging the alarm.
  8. On the RSA configuration page, enter the following information:
    Import on map
    Select the map that you want to use to display the sensors in Security Center.
    Events
    Turn on the custom events you want to monitor for this tracking system.
    NOTE: You can modify this later on the Properties page of the tracking system.
    Perimeter configuration
    Choose the colors for the perimeter when it is Armed, Disarmed, and when a System warning is reported.
    NOTE: The warning state is active on the following events from Sensurity Universe Service:
    • Environmental alarm
    • Error alarm
    • Tamper alarm
    • Power alarm
    Change color on intrusion
    Enable this option to select the intrusion color. When the perimeter device receives a zone alarm, the RSA Surveillance plugin can change the color of the segment where the intrusion is detected.
    Intrusion
    The color of the perimeter segment when an intrusion is detected.
  9. Click Finish.

After you finish

Create RSA zones.