Configuring SICK lasers for integration with Security Center - Restricted Security Area Surveillance 3.5

Restricted Security Area Surveillance Plugin Guide 3.5

series
Restricted Security Area Surveillance 3.5
revised_modified
2020-08-27

To prepare your SICK lasers for integration with Security Center, you must configure specific settings.

Before you begin

  • Make sure your SICK lasers are operating as expected.
  • Make sure the lasers are compatible with the plugin.

What you should know

This task describes in a general way how SICK devices need to be configured to communicate with the plugin. For specific details about the configuration of your devices and software, refer to your manufacturer's documentation.

Procedure

  1. Deploy and configure the laser. For more information, refer to the SICK documentation.
  2. If your organization's network security policies require that the IP devices, routers, and switches in your network block unused ports, make sure to open the TCP port that the RSA Surveillance plugin and SICK laser use to communicate.
    NOTE: SICK devices use port 2111 to communicate.
  3. Take note of the following information, which you will need later to configure the tracking system:
    • IP address of the SICK laser.