Known issues are software issues that have been discovered in the current release or a previous release, and have not yet been resolved.
AutoVu™ Genetec Patroller™ 6.5 includes the following known issues:
Issue | Description |
---|---|
1678288 | When used with overtime parking, the Plate link feature can sometimes go offline when the system tries to upload a read that does not have an associated ZoneGuid. |
1037494 | If the cellular connection between Genetec
Patroller™ and Security
Center is lost, there is a short delay
before GNSS positions are buffered. This can result in a lost positioning during LPR
route playback. This issue is not present when offloading at the end of a patrol, but
effects Patroller systems that are configured to send Patroller positions live to
Security
Center Server. Workaround: You can correct the displayed route by offloading Patroller data at
the end of the patrol.
|
473328 | In the Patroller UI, some buttons, fields names, and messages are not translated into the supported languages. |
109291 | (Windows 8 and 8.1 only) Your in-vehicle computer’s touchscreen may become
unresponsive when using Genetec
Patroller™ or Genetec
Patroller™ Config Tool. Workaround: Use the
in-vehicle computer’s built-in touchpad and mouse buttons when using Genetec
Patroller™ or Genetec
Patroller™ Config Tool.
|
108726 | When equipped with GPS and odometry, Genetec
Patroller™ may not be able to read plates unless it
can determine its initial GPS position; you should be able to read plates with only
odometry enabled. Workaround:
|