The following software issues were resolved in Security Center 5.9.1.0.
Solution/Unit | Issue | Description |
---|---|---|
Access | 2432194 | When the Active Directory role performs a full sync, there is Access Manager performance degradation, causing Synergis™ Cloud Link units to disconnect. |
Access | 2426975 | If an output is set for both a zone and a door, and the door has an unlock schedule, the door might not unlock or relock at the scheduled time. |
Access | 2414880 | Reports for Credential information in the Credential activities task might fail with a timeout error. |
Access | 2370454 | Unit enrollment fails if the computer system language is set to Turkish |
Access | 2358677 | In Security Desk, the People counting task shows the cardholder's Active Directory entity name instead of their full first and last name. |
Access | 2354380 | When doing a CSV import, cardholder status values are overridden when imported along with activation and expiry values. |
Access | 1191407 | When you generate a report in the Cardholder Management task that includes Activation date or Expiration date, the report results only include cardholders. The report should also include credentials, which also include activation and expiration dates. |
Access | 1190516 | For elevators using HID V1000 Networked Controllers, if floors are configured with different access rules, and one floor is out of schedule and should deny access, users cannot access any floors in the building. |
All | 2446761 | Entry Delay configured for virtual zones does not work after a Zone Manager role restart. |
All | 2421611 | When installing Security Center on certain non-English Windows OS systems, the install fails with the error InstallHelper Exception (-2146233033): Input string was not in a correct format. This occurs for languages that do not use the point character for decimals. |
All | 2346935 | The Security Center Mobile Client does not display video watermarks. |
Axis | 2417661 | Double Panorama dewarping does not work for Axis M3048-P cameras. |
Axis | 2371895 | After restarting an Axis unit with a MPEG4 stream, default configurations are
sent to the unit for that stream. Workaround: Reset the custom values
manually from the Video tab after reconnecting the
device.
|
Axis | 2370878 | Axis units without video inputs do not receive Audio alarm events. |
Bosch | 2370918 | Events generated by Bosch units running firmware 7.50 are not received in Security Desk. |
Hanwha | 2428341 | Hanwha PNM-9030V models use a license for every encoder instead of one for the whole unit. |
Intrusion | 2319725 | When adding an intrusion detection unit to a partition from the partition's Properties page, only the unit is added to the partition. Intrusion detection areas must be added manually. |
LPR | 2450389 | When upgrading the LPR role database, it might fail with a timeout error if there are too many reads or hits saved. |
LPR | 2425909 | You cannot configure the retention period for hotlist and permit list delta files created for Patrollers. They are kept for 30 days by default. |
LPR | 2412714 | AutoVu™ XML export does not support reads and hits timestamped with the UTC time zone. |
LPR | 2359975 | LPR units display as offline if, when added manually in the Config Tool, one of the connections is not established and Force Connect is enabled in the Portal. |
LPR | 2320880 | When configuring an event-to-action to receive an email for a read or hit, the plate image is only included if the event-to-action is configured as from the camera and not the unit. |
LPR | 2299054 | The License Plate Manager role goes into a Warning state if it uses the same database as another License Plate Manager role. |
LPR | 2257939 | Security Desk might fail when monitoring entities that generate a high number of events on the system or the network connection between the client and server is slow. |
ONVIF | 2438475 | Some ONVIF cameras stop working when configured to use IPv6. |
ONVIF | 2363352 | ONVIF units do not receive input events when pull point subscription requests fail. |
Video | 2434491 2434490 |
Adding a WPFControl with a MediaPlayer object to a WinForm in Visual Studio Designer fails with a Could not load file or assembly to GenetecServerHost error. |
Video | 2410684 2410690 |
Cameras stop recording to the Auxiliary Archiver when unavailable transmission channels or blocked internal processes are handled incorrectly. |
Video | 2453296 | In Security Desk, the alarm video popup shows playback instead of live video when the Center map on received alarm setting is on. |
Video | 2446961 | When exporting from the Incidents task, export sequence dialog does not follow the camera order created in the task. |
Video | 2436575 | The GenetecVideoUnitControl32.exe process fails when an invalid MAC address is received from the unit. |
Video | 2433994 | When federating to a system running Security Center 5.5 or earlier, the redirector process shows a continuous memory leak. |
Video | 2432910 | When asking for a particular dewarped zone in Security Desk, dewarping is not applied to the area selected with the zoom box |
Video | 2432906 | Dewarping PTZ zoom presets are not applied if the monitoring tile is not already in dewarping mode. |
Video | 2428603 | When Generic Plus units are reconnected to your system, it causes the GenericVideoUnitControl32.exe process memory to continuously increase. |
Video | 2428144 | Archivers managing multiple cameras with multiple overlays might see the Archiver agent process experience a continuous memory leak leading to an Out of memory error. |
Video | 2427492 | Some cameras lose live video when the Encryption field is set to In transit from Archiver. |
Video | 2425912 | When changing camera IP range configurations, either no units are discovered or units in the range of the previous configuration are discovered. |
Video | 2415459 | After a system reboot, cameras added in HTTPS, using a certificate with the hostname set as a common name, do not reconnect. |
Video | 2398487 | PTZ cameras show video stuttering when using the default value for the Jitter buffer delay setting. |
Video | 2370865 | Live view from Ioimage cameras displays as colored pixels in Monitoring tiles. |
Video | 2367171 | Archive transfers configured to retrieve edge recordings based on bookmarks don't transfer some sequences if the bookmarks are too close to each other in time. |
Video | 2364382 | OEF federated cameras mix streams after losing connection to an Omnicast™ system. |
Video | 2361962 | Archive consolidation fails due to a communication error preventing the completion of the video transfer. |
Video | 2361041 | Files are deleted per retention period even though Automatic cleanup is disabled on the Auxiliary Archiver. |
Video | 2359757 | Events coming from an Archiver might be delayed causing alarms and event-to-actions to execute later than expected. |
Video | 2359105 | Cameras are displayed as offline after a failover recovery. |
Video | 2358664 | Following a Media Router failover of a multicast network, video streams in TCP instead of multicast. |
Video | 2354885 | Streaming in multicast causes higher bandwidth utilization when local and federated camera use the same address range. |
Video | 2349908 | When exporting a video file to MP4 with ACC audio, the export fails with an invalid range error message. |
Video | 2348203 | After upgrading to Security Center 5.8.1.0 or later, the Media Router role's Server name does not show on the Properties page. |
Video | 2347986 | When a camera is requested by Security Center 5.8 and Security Center 5.5 at the same time, incorrectly allocated multicast addresses create IP conflicts and distorted video display. |
Video | 2346910 | When the Cloud Archives Config Tool is updated to 5.9.0.0, configured
properties return to their default values. Workaround: Replace the 5.9.0.0
CloudArchiverPlugin.gconfig file with a copy of the config
file from the previous version.
|
Video | 2306512 | When sending a Describe request for live video using the Media Gateway role, the response shows an empty Session name parameter. |
Video | 2296401 | When Archiver failover is configured, PTZ stops working on maps and in SDK applications using aggregate PTZ. |
Video | 2258996 | When viewing video from a Vivotek unit in Security Desk, there is a long delay before hearing live audio if the Encryption parameter is set to In transit from Archiver. |
Vivotek | 2450059 | Vivotek units added with Vivotek extensions cannot stream when basic authentication is enabled. |