Report pane columns for the Alarm report task - Security Center Mobile 4.1

Security Center Mobile User Guide for Web Client 4.1

series
Security Center Mobile 4.1
revised_modified
2017-05-24

After generating a report, the results of your query are listed in the report pane. This section lists the columns available for the relevant reporting task.

NOTE: If you generated the Alarm report using Web Client, not all of the report columns are available.
ID
Alarm instance number. Uniquely identifies each alarm instance.
Alarm
Alarm entity name.
Priority
Alarm priority. All alarms imported from Omnicast have their priority set to 1 by default. You can change their priority at a later time in the Config Tool.
Alarm color
Color of the alarm.
Source
The source entity that triggered the alarm, when the alarm is triggered by an event-to-action. It shows a username when the alarm is triggered manually.
Source time
Time of the alarm-triggering event. The only time Source time and Triggering time are different is when the event occurred while the access control unit was offline.
Triggering event
Event that triggered the alarm (if triggered through an event-to-action). Manual action is indicated when the alarm was manually triggered by a user.
State
Current state of the alarm.
Active
Alarm is not yet acknowledged. Selecting an active alarm shows the alarm acknowledge buttons in the report pane.
Acknowledged (Default)
Alarm was acknowledged using the default mode.
Acknowledged (Alternate)
Alarm was acknowledged using the alternate mode.
Acknowledged (Forcibly)
Alarm was forced to be acknowledged by an administrator.
Under investigation
Alarm that is under investigation, meaning that someone has seen it but not necessarily able to take care of it.

(5.6 and earlier) Alarm under investigation with an acknowledgement condition that is still active. These alarms cannot be acknowledged until the condition is cleared.

Acknowledgement required
Alarm with an acknowledgement condition that was cleared and that is ready to be acknowledged.
Acknowledged by
User who acknowledged the alarm. When the alarm is acknowledge automatically by the system, Service is indicated.
Acknowledged on
Time the alarm was acknowledged.
Context
Alarm annotation.
External instance ID
Only for federated alarms. The original alarm instance ID on the federated system.
Investigated by
The user who put the alarm into the under investigation state.
Investigated on
The timestamp when the alarm was put into the investigation state.
Occurrence period
Period when the event occurred.
Trigger time
Time the alarm was triggered in Security Center.
Custom fields
The pre-defined custom fields for the entity. The columns only appear if custom fields are defined for the entity, and if the custom fields were made visible to you when they were created or last configured.