Before you can trigger outputs in Security Center, you must associate them to specific filters and triggers on the panel, using ATS8500 Standalone Downloader.

Procedure

  1. In ATS8500 Standalone Downloader, create a trigger.
  2. Create a filter that uses the trigger you created to activate the output.
    1. Configure the Logical function of the activation filter by setting the following parameters in the Condition Filter dialog box:
      Group
      Select External trigger.
      Element
      Select the trigger you created.
      Event
      Select Remote output control flag.
  3. Create a filter that uses the trigger you created to deactivate the output.
    1. Configure the Logical function of the deactivation filter by setting the following parameters in the Condition Filter dialog box:
      Group
      Select External trigger.
      Element
      Select the trigger you created.
      Event
      Select Remote output control flag.
      Invert
      Make sure this check box is selected.
  4. Associate the filters to the output.
    1. Select the filter you want to activate and deactivate, and configure the following parameters:
      Start filter
      Select the activation filter.
      Stop filter
      Select the deactivation filter.