To receive intrusion events and alarms from the Vanderbilt SPC Intrusion Panel in Security Desk, you must configure the intrusion detection unit in Config Tool.
Before you begin
WARNING: If you open Config tool from a server that does not host
the
Intrusion Manager, you will not see the
correct Network card options for configuration in the
Properties tab.
Procedure
- From the Config Tool homepage, open the Intrusion detection task.
- From the Intrusion Manager role in the entity browser, select the intrusion detection unit to configure.
-
Click the Properties tab to configure the following
properties.
- IP address
- The IP address of the selected intrusion detection unit.
User information
- Username
- The name of the SPC panel user to connect the panel.
- PIN
- The PIN you configured on the panel for the selected user.
Listener
- Network card
- The Genetecâ„¢ Server network card used to communicate with SPC intrusion panels.
- Port
- The Genetecâ„¢ Server TCP port used for SPC panel connections.
NOTE: Refer to the FlexC and ATS configuration in the SPC Pro application.Outputs
- Keep output states synchronized
- Select this option to keep the output states from the intrusion detection unit synchronized with Security Center.
- Synchronization interval
- How often the output state of the intrusion detection unit gets synchronized with Security Center.
Intrusion areas
- Synchronization interval
- How often the state of the intrusion detection area gets synchronized with Security Center.
- Default delayed arming time
- The default duration of the delay used by the delayed arming command. If a custom delay is set on the Security Desk widget, this default time is not used.
- Allow re-raising alarm events on an area already in alarm
- Select this option to allow Security Center to trigger another alarm on an area already in an Active alarm state. If this option is cleared, new alarms (for the same intrusion detection area) will only be triggered when the previous alarm has been acknowledged.
- Perimeter arming mapping
- Select the Partset mode to be used by the intrusion detection unit when a perimeter arming command is used by Security Center. Partset A or Partset B can be used in SPC panel configuration.
Back up panel configuration
- Back up now
- Click to back up the panel configuration. Select the local folder to start the backup.
- Restore now
- Click to send a configuration file to the intrusion panel. Select the CFG file to start the restore.
IMPORTANT: The Back up panel configuration section only appears if you are logged into the panel as an Engineer user, as configured in the User information section. - Click Apply.