To use Vanderbilt SPC intrusion panels in Security Center, you must configure how the Intrusion Manager listens for SPC panel connections.

Procedure

  1. From the Config Tool homepage, open the Intrusion detection task.
  2. Select the Intrusion Manager role, click the Extensions tab, and click the SPC page.
  3. Configure the following options:
    Grace period
    Select the period in which events can occur while the panel is offline, so that they are treated as normal events after the panel reconnects.

    The events within the Grace period appear under the event list in the Monitoring task. They are recorded in the database, and event-to-actions that were set up for the event are triggered.

    Alarm grace period
    Select the period in which alarms can occur while the panel is offline, so that they are treated as normal alarms after the panel reconnects.

    Alarms occurring within the Alarm grace period appear under the alarm list in the Alarm monitoring and Monitoring tasks. They are recorded in the database.

    Persistence grace period
    Events and alarms from the panel that occurred within the Persistence period while the panel was offline, are only recorded in the database when the panel reconnects. Events and alarms that occur outside of the Persistence period are not recorded.