System components connect to the Cloud Link Roadrunner™ unit according to the pinout on the back of the unit.
A | Locks: LK1 / LK2 |
LS+: Lock sense + CTL: Lock control P-: Lock power - LS-: Lock sense - P+: Lock power + NOTE: Lock output
power: 24 Vdc max 650 mA per lock
|
B | Door sensors: DPS1 / DPS2 |
+: Door position sensor + -: Door position sensor - |
C | Card readers: RD1 / RD2 |
+12V: Reader power 12 V NOTE: Reader Output Power: 12 Vdc
max 240 mA per card reader
GND: Reader ground 485A: RS485 Data + 485B: RS485 Data - S: RS485 shield |
D | Inputs | IN1: Input 1 GND: Input ground IN2: Input 2 GND: Input ground IN3: Input 3 GND: Input ground IN4: Input 4 GND: Input ground |
E | Relays |
NO1: Normally open relay 1 C1: Common relay 1 NC1: Normally closed relay 1 NO2: Normally open relay 2 C2: Common relay 2 NC2: Normally closed relay 2 |
F | Input Power | +: 22-26 V dc + -: 22-26 V dc - NOTE: 420 mA
mean / 724 mA peak
|