Using the included server rack flange, you can mount a single Cloud Link Roadrunner™ on a server rack in the
enclosure.
What you should know
- Screws for securing the mounting flange to the server rack are not provided. The
mounting flange holes accept screws up to M6 (¼-20).
- This mounting method requires one single-side rack unit (1U).
Procedure
-
Remove the two screws from the left or right side of the unit.
-
Attach the one-unit rack mount flange using four of the provided flat-head
screws.
IMPORTANT: Ensure that the screws are fully tightened.
NOTE:
- The top two mounting holes are unused.
- The mounting flange is reversible.
-
Secure the flange to the server rack.
NOTE: Screws for securing the mounting flange to the server rack are not provided.
The mounting flange holes accept screws up to M6 (¼-20).