The Morse Watchmans KeyWatcher Touch plugin adds custom events in Security Center. These events can be used as query filters in activity reports or to create event-to-actions.
Security Center custom event | Morse Watchmans KeyWatcher Touch custom event | Source entity | |||
---|---|---|---|---|---|
Cardholder | Area | Locker | Key | ||
Key added | Add | x | x | x | x |
Key returned | Return | x | x | x | |
Key removed | Remove | x | x | x | |
Key removed illegally | - | x | x | x | |
Key replaced | Replace | x | x | x | |
Key overdue | Alarm: Overdue | x | x | ||
Key not taken | Alarm: Not Taken | x | x | x | |
Key deleted | Delete | x | x | x | x |
Key removed: emergency release | Remove: Emergency release | x | x | x | |
Key not returned | Alarm: Not returned | x | x | x | |
Secure key return violation | Warning: Return Denied - Secure Key Return Violation | x | x | ||
Invalid key returned | Alarm: Invalid Key Returned | x | x | ||
Remove invalid key | Alarm: Invalid Removed | x | x | ||
Key reservation | Reservation | x | x | ||
Reservation key not returned | - | x | x | ||
Key reservation active | Reservation Active | x | x | x | |
Key reservation inactive | Reservation Inactive | x | x | x | |
Key returned by different user | Warning: Key Return By Different User | x | x | x | |
Return - overdue key | Waming: Return - Overdue Key | x | x | x | |
Slot release | Alarm: Shorted Slot - Key Removed | x | x | ||
Shorted slot | Alarm: Shorted Slot | x | |||
Door not opened | Alarm: Door Not Opened | x | x | ||
Door left open | Alarm: Door Left Open | x | x | ||
Illegal entry | Alarm: Illegal Entry | x | |||
Door opened | Door Opened | x | x | ||
Door closed | Door Closed | x | x | ||
Controller AC power loss | Alarm: Controller AC Power Loss | x | |||
Controller AC power restored | Alarm: Controller AC Power Restored | x | |||
Communication lost | Alarm: Communication Loss | x | |||
Communication restored | Alarm: Communication Recovered | x | |||
Message received from the locker was corrupted | Alarm: Communications Bad CRC X3 | x | |||
Controller battery fail | Alarm: Controller Battery Fail | x | |||
Controller battery low | Alarm: Controller Battery Low | x | |||
Controller reset complete | Alarm Cancel: KW Controller Reset Complete | x | |||
Release door latch activated | Release Door Latch Activated | x | x | ||
User logon | User Logon KeyWatcher | x | x | ||
User duress logon | Alarm: User Duress Logon | x | x | ||
User logoff | User Logoff KeyWatcher | x | x | ||
Logon failure | Warning: Logon Failure - Number on attempts by User exceeded | x | x | ||
User not recognized in KeyWatcher system | Logon Attempt Failed - User not recognized in Key Watcher System | x | |||
Logon attempt failed - User disabled in site | Logon Attempt Failed - User ID disabled in Site | x | x | ||
Logon attempt failed - User disabled in system | Logon Attempt Failed - User disabled in System | x | x | ||
User logon date range expired | Logon Attempt Failed - User logon date range expired | x | x | ||
User ID disabled | Logon Attempt Failed - User ID Disabled | x | x | ||
Incorrect PIN | Logon Attempt Failed - Incorrect PIN entered | x | x | ||
Alarm triggered | - | x | x | x | |
Alarm cancelled by user | - | x | x | x | |
Alarm cancelled by system | - | x | x | ||
Alarm cancelled by system over limit | - | x | x |