The following additional configuration steps are required for some of your units to work in Security Center.
- Firmware upgrades
- To upgrade the firmware for Arecont units, you must use the Arecont Firmware Loader. Before you upgrade, make sure the unit is not streaming video and not connected to an Archiver.
- Key frames and H.264 units
- To use key frame-related functions (such as still frame alarms) with Arecont
H.264 cameras, you must set a high frame rate, or modify the frame interval
between key frames. To change the interval setting, use the following URL:
http://<camera.ip>/setreg?page=3®=21&val=<value
meant to replace the 50>
. For example, if your camera IP is 10.1.24.35 and you want to change the
interval setting to five, you would type:
http://10.1.24.35/setreg?page=3®=21&val=5.NOTE: If you are using an Arecont Surround Video IP Camera, you must replace the 21 in the URL with 100 (http://10.1.24.35/setreg?page=3®=100&val=5).
- Motion detection
- Default motion detection sensitivity doesn't trigger motion events. You must configure this setting at 50% when the unit is added.