Users are not receiving alarms from UTC Advisor Master and Advanced panels - UTC Advisor Master and Advanced 3.0

UTC Advisor Master and Advanced Intrusion Panel Extension Guide 3.0

Applies to
UTC Advisor Master and Advanced 3.0
Last updated
2022-05-17
Content type
Guides > Plugin and extension guides
Language
English
Product
UTC Advisor Master and Advanced
Version
3.0

One or more users did not receive an alarm that was triggered in Security Center. The alarm is in the Alarm report task, but was not displayed in the user's Alarm monitoring task.

Cause

This issue typically occurs when a user or user group is not a recipient for the alarm entity. When the Recipients list is empty and the alarm is triggered in Security Center, no users are notified.

Solution

Add recipients to an alarm:

  1. Open the Alarms task, select the alarm entity in the entity browser, and then click Properties.
  2. In the Recipients section, add the users who need to be notified when the alarm occurs.