Some event-to-actions can be configured so that a second event must be triggered before the alarm that was triggered can be acknowledged. The second event is the acknowledgment condition.
For example, you can configure a Signal lost event to trigger an alarm, and specify that the alarm can only be acknowledged after the Signal recovered event is generated.
The following table lists the event types that gives you the option to configure an acknowledgment condition that must be cleared before the alarm can be acknowledged.
Source event type | Entity type | Acknowledgment condition |
---|---|---|
AC fail | Access control unit, Intrusion detection unit | AC ready |
Application lost | Roles | Application online |
Asset offline | Asset | Asset online |
Asset online | Asset | Asset offline |
Battery fail | Access control unit, Intrusion detection unit | Battery ready |
Deadbolt locked / unlocked | Zone | Input (Normal or Active) |
Door closed | Door, Zone | Input (Normal or Active) |
Door forced open | Door, Zone | Door closed Input (Normal or Active) |
Door locked / unlocked | Door, Zone | Input (Normal or Active) |
Door manually unlocked | Door, Zone | Input (Normal or Active) |
Door opened | Door, Zone | Door closed Input (Normal or Active) |
Door open too long | Door | Door closed |
Door unsecured | Door | Door secured |
Doorknob in place / rotated | Zone | Input (Normal or Active) |
Entity warning | Any entity that has an input | Input (Normal or Active) |
Glass break | Zone | Input (Normal or Active) |
Hardware tamper | Access control unit, Intrusion detection unit, Zone | Tamper normal Input (Normal or Active) |
Intrusion detection area alarm activated | Intrusion detection area | Disarmed (not ready) Disarmed (ready to arm) Perimeter armed Master armed |
Intrusion detection area input bypass activated | Intrusion detection area | Input normal |
Intrusion detection unit tamper | Intrusion detection unit | Tamper normal |
Lock released / secured | Zone | Input (Normal or Active) |
Manual station activated | Door, Zone | Manual station normal Input (Normal or Active) |
Manual station reverted to normal state | Door, Zone | Input (Normal or Active) |
Motion off / on | Zone1 | Input (Normal or Active) |
Record updated | Record type, Zone | Input (Normal or Active) |
Recording problem | Camera | Recording problem resolved (corresponds to Recording on or Recording off) |
Signal lost | Camera | Signal recovered |
Unit lost | Access control unit, Intrusion detection unit, ALPR unit, Video unit | Unit online |
Window closed / opened | Zone | Input (Normal or Active) |
Zone armed / disarmed | Zone | Input (Normal or Active) |
Zone maintenance completed / started | Zone | Input (Normal or Active) |
Zone offline | Zone | Input (Normal or Active) |
1 Only Motion on and Motion off events associated to zone input states can have an acknowledgment condition.